Best
Product Use
Pittco System Product Summary
links below reveal definitions, or
click here to view all
Suggested Applications Glazing Options Performance Criteria
Air Water Structural Thermal
(cfm/ft2) (psf) (psf) U-Factor CRF
Storefront
Applications
EMS 114 1 3/4" x 4 1/2" center set, single-span system for monolithic glazing offering screw-spline assembly and easy installation. Single-span storefronts, punched openings, entrance sidelites. Inside or outside set. 0.02 @ 6.24 psf No leakage @ 4 psf ± 20 psf
< L/175 deflection
1.09 11
TMS 114 2" x 4 1/2" center set, single span system for monolithic or insulating glazing offering screw-spline assembly and easy installation. Single-span storefronts, punched openings, entrance sidelites. Inside or outside set. 0.02 @ 6.24 psf No leakage @ 10 psf ± 25 psf
< L/175 deflection
0.62 34
TMS 114 T 2" x 4 1/2" thermally broken, center set, single span system for monolithic or insulating glazing offering screw-spline assembly and easy installation. Single-span storefronts, punched openings, entrance sidelites. Inside or outside set. 0.02 @ 6.24 psf No leakage @ 10 psf ± 25 psf
< L/175 deflection
0.57 58
TMS 114 UF 2" x 4 1/2" thermally broken, front set, single span system for monolithic or insulating glazing offering screw-spline assembly and easy installation. Single-span storefronts, punched openings, entrance sidelites. Inside or outside set. 0.02 @ 6.24 psf No leakage @ 10 psf ± 25 psf
< L/175 deflection
0.43 56
Flushlok II 2" x 4 1/2" thermally broken, center set, single span system for monolithic or insulating glazing offering quick assembly and easy installation. Single-span storefronts, punched openings, entrance sidelites. Inside or outside set. 0.03 @ 6.24 psf No leakage @ 10 psf ± 20 psf
< L/175 deflection
0.59 57
TMW 250 2" x 4 13/16" thermally broken, front set, single span system for monolithic or insulating glazing offering screw-spline assembly, and easy installation. Single-span storefronts, punched openings, horizontal strip windows. Inside or outside set. 0.04 @ 6.24 psf No leakage @ 8 psf ± 40 psf
< L/175 deflection
0.66 53
TMW 250 EFG 2" x 4 13/16" butt glazed, thermally broken, front set, single span system for monolithic or insulating glazing offering screw-spline assembly, and easy installation. Single-span storefronts, punched openings, horizontal strip windows. Inside or outside set. <0.01 @ 6.24 psf No leakage @ 10 psf ± 50 psf
< L/175 deflection
0.58 53
Curtain Wall
Applications
70 Wall 2 1/2" x (5 11/16" to 10 11/16") thermally broken, front set, multi-span system for monolithic or insulating glazing, stick assembly, offering maximum windload capacity. Multi-span curtain walls, single span atriums, low/high rise applications. Outside set. 0.04 @ 6.24 psf No leakage @ 10 psf ± 50 psf
< L/175 deflection
0.47 64
EFG 800 2 1/2" x (5 11/16" to 10 11/16") thermally broken, 2 or 4 side butt glazing, front set, multi-span system for monolithic or insulating glazing, stick assembly, high windloads. Multi-span curtain walls, single span atriums, low/high rise applications. Outside set. 0.02 @ 6.24 psf No leakage @ 10 psf ± 50 psf
< L/175 deflection
0.51 65
TMW 450 2" x 6 13/16" thermally broken, front set, multi-span system for monolithic or insulating glazing offering screw-spline assembly, easy installation, high windloads. Multi-span curtain walls, single span atriums, low/high rise applications. Inside or outside set. 0.04 @ 6.24 psf No leakage @ 15 psf ± 50 psf
< L/175 deflection
Not Tested 58
TMW 450 EFG 2" x 6 13/16" 2 or 4 side butt glazing, thermally broken, front set, multi-span system,monolithic/insulating glazing, screw-spline assembly, easy installation, high windloads. Multi-span curtain walls, single span atriums, low/high rise applications. Inside or outside set. <0.01 @ 6.24 psf No leakage @ 15 psf ± 50 psf
< L/175 deflection
0.58 54
TMW 453 2 1/2" x 6 13/16" thermally broken, front set, multi-span system for monolithic or insulating glazing offering screw-spline assembly, easy installation, high windloads. Multi-span curtain walls, single span atriums, low/high rise applications. Inside or outside set. 0.03 @ 6.24 psf No leakage @ 15 psf ± 50 psf
< L/175 deflection
0.43 68
TMW 453 EFG 2" x 6 13/16" 2 or 4 side butt glazing, thermally broken, front set, multi-span system, monolithic/insulating glazing, screw-spline assembly, easy installation, high windloads. Multi-span curtain walls, single span atriums, low/high rise applications. Inside or outside set. 0.04 @ 6.24 psf No leakage @ 15 psf ± 50 psf
< L/175 deflection
0.39 72
Commercial Entrances Narrow, Medium & Wide Stile Doors
(1 3/4" thick)
Manufactured to desired specifications using a mortise and tenon design and steel tie-rod construction. Available with monolithic or insulated glazing in three stile widths. Entrances to storefronts, exterior or interior vestibules. Inside or outside set. 0.91 @ 1.57 psf Not Tested Not Tested Not Tested Not Tested
Monumental Doors
(2" thick)
Uses a mortise and tenon design and steel tie-rod construction and increased wall thickness. Monolithic or insulated glazing and heavy duty hardware available. Entrances to storefronts, exterior or interior vestibules. Inside or outside set. 0.91 @ 1.57 psf Not Tested Not Tested Not Tested Not Tested